Skip to main content
When TIA Portal can’t find the PLC, or the HMI can’t connect, the cause is very often the IP settings: the devices are in different subnets, or two devices share the same IP. Enter every device on the machine network to see who can talk to whom.

How subnets work

An IP address has a network part and a host part. The subnet mask decides where the split is:
  • 255.255.255.0 (/24): the first three numbers are the network. 192.168.0.1 and 192.168.0.2 are in the same network, 192.168.1.10 is not.
  • 255.255.0.0 (/16): the first two numbers are the network, so 192.168.0.1 and 192.168.1.10 are in the same network.
Two devices can talk directly (without a router) only when each one sees the other inside its own network. The first address of a network (the network address) and the last (the broadcast address) can’t be given to a device.
This checker looks at direct connections on one Ethernet network. Devices in different subnets can still talk through a router or gateway, which this tool doesn’t model. PROFINET device names, VLANs and firewalls can also block a connection.

Modbus RTU frame builder

Build Modbus RTU and TCP requests with the correct CRC.

All free tools

Every calculator for PLC and IIoT engineers in one place.